Check the condition of the cables along the Z‑axis assembly

WHAT YOU NEED 

Safety Equipment:Standard Personal Protective Equipment

Other Equipment:Step Ladder

CAUTIONSHARP BLADE: Keep clear of the saw blade while working inside the saw chamber.

  1. Using the Manual Mode window, move the Y-axis to the middle position and the Z-axis to the lowest position.
  2. Press the E‑stop button on the operator console.
  3. Open the saw chamber door.
  4. Open up the dome.
  5. Inspect the following cables for any signs of damage:

    • the cables connected to the saw head junction box
    • the cables connected to the slip ring
    • the cables connected to the Z‑axis junction box
    • the cables connected to the Z‑axis motor
    • the cables in the cable tray and cable chain

  6. Inspect the cable tray and cable chain for any damaged or broken parts that may cause rubbing on the cables.
  7. Remove any bits of timber that may cause damage to the cables.