Check the height detection is correct

WHAT YOU NEED 

Standard Personal Protective Equipment

CAUTIONWhen using the manual mode, make sure that everything and everyone is clear of moving parts to prevent damage or injuries.

  1. Open the PEWIN32PRO program.
  2. Select Watch Window from the View drop-down menu at the top of the PEWIN32PRO window.
  3. Press the Insert key and add the MeasuredTimberThickness (P757) variable to the Watch Window.
  4. Using the Manual Mode window, clamp a board into the saw.
  5. Make sure the MeasuredTimberThickness variable in the Watch Window is reading the actual thickness of the board (in mm).
  6. Hold down the red STOP button on the operator console for 3 seconds and remove the timber from the saw.
  7. Repeat steps 4 to 6 with two boards stacked one on top of the other.
  8. If the height detection is not correct for either test, contact Vekta Automation for help in recalibrating.