Error 92: Blade Speed Not Ready
Variable M128
The saw has not detected that the blade started up properly.
What to do now
Hold the STOP button down to stop the saw. Try to restart a second time.
What to do next
- If the saw blade has started spinning, check that the blade speed in the monitoring panel is greater than the value set in variable P642.
- If the blade has not started spinning, stop the saw and open the door to the saw chamber. Confirm that the plugs located on the blade motor are secure and that there is no visual sign of damage to the cables.